Oklahoma Administrative Code (Last Updated: March 11, 2021) |
TITLE 252. Department of Environmental Quality |
Chapter 641. Individual and Small Public On-Site Sewage Treatment Systems |
Subchapter 12. Dispersal Fields |
SECTION 252:641-12-4. Low pressure dosing fields
Latest version.
- (1) located in the identified dispersal site;(2) installed more than five feet (5') from the septic tank or aerobic treatment unit; and(3) preceded by a low pressure dosing tank.(b) Header line. The header pipe (i.e., the pipe between the pump tank and the manifold) shall:(1) have a diameter the same as the diameter of the outlet of the low pressure dosing pump; and(2) be no longer than thirty feet (30').(c) Total linear length. All low pressure dosing fields shall meet the total linear length requirements set forth in Appendix H, Figures 8 and 9.(d) Trench length. Each trench in a low pressure dosing field shall be forty feet (40') long.(e) Trench spacing. The trenches in a low pressure dosing field shall be spaced six feet (6') apart, center to center.(f) Trench width. All trenches in a low pressure dosing field shall be twenty-four inches (24") wide.(g) Trench depth. Each trench in a low pressure dosing field shall have a uniform depth of at least fourteen inches (14") and no more than thirty inches (30"). The bottom of the trenches shall be level.(h) Dispersal and storage. Each trench in a low pressure dosing field shall contain a zone for the dispersal and storage of effluent comprised of low pressuring dosing pipe and storage media.(1) Low pressure dosing pipe. Low pressure dosing pipe shall:(A) meet the minimum specifications listed in Appendix C;(B) have one-fourth inch (1/4") diameter holes spaced five feet (5') apart the entire length of the pipe;(C) extend the entire length of the trenches; and(D) have all of the joints glued.(2) Storage media. The storage media shall:(A) be at least six inches (6") deep and at least twenty-four inches (24") wide the entire length of the trench;(B) be installed with at least two inches (2") of the storage media above and two inches (2") of storage media below the low pressure dosing pipe; and(C) be level:(i) in each trench; and(ii) across the low pressure dosing field.(i) Retention structures prohibited. Retention structures may not be used in low pressure dosing fields.(j) Backfill. For low pressure dosing fields:(1) the depth of the backfill shall be consistent and shall not vary more than four inches (4"); and(2) the backfill shall consist of at least eight inches (8") of topsoil.(k) Layout examples. There are layout examples located in Appendix K, Figure 3, and Appendix M, Figure 3.