SECTION 252:656-19-4. Sludge pumps and piping  


Latest version.
  • (a)   Sludge pumps.
    (1)   Duplicate units. Provide duplicate units.
    (2)   Minimum head. Pumps must provide at least 24 inches of positive head.
    (3)   Sampling facilities. Provide a means to sample sludge. All sampling pipes and valves must be at least 1.5 inches.
    (b)   Sludge piping. Sludge withdrawal piping must be at least 8 inches in diameter for gravity systems and 6 inches for pump suction and discharge lines. A minimum velocity of 3.0 fps for gravity lines is required.
[Source: Added at 17 Ok Reg 1140, eff 6-1-00; Amended at 23 Ok Reg 937, eff 6-15-06]