SECTION 325:85-15-19. Critical memory integrity  


Latest version.
  •   Comprehensive checks of Critical Memory shall be made during each Player Terminal restart such as power-up cycle. The Player Terminal control program shall test for possible corruption of Critical Memory. Test methodology shall detect 99.99 percent of all possible failures. In addition, all Critical Memory (Non-Volatile) shall:
    (1)   Have the ability to retain data for a minimum of thirty days after power is discontinued from the machine.
    (2)   Only be cleared by accessing the locked logic compartment in which it's housed;
    (3)   Result in a RAM Error if the control program detects an unrecoverable memory error; and
    (4)   The RAM should not be cleared automatically, but shall require a full RAM clear (RAM Reset) performed by an authorized Person.
[Source: Added at 23 Ok Reg 1160, eff 4-6-05 (emergency); Added at 23 Ok Reg 2089, eff 5-11-06 (emergency); Added at 23 Ok Reg 2613, eff 6-25-06]