SECTION 40:50-1-3.1. Violation reset  


Latest version.
  • (a)   A violation reset shall be activated by any of the following:
    (1)   Three (3) penalty fails, at startup, within a fifteen (15) minute time frame.
    (2)   A circumvention.
    (3)   A retest violation.
    (b)   When a violation reset is activated, the device will initiate a unique audible and/or visual cue that will warn the driver that the device will enter a permanent lockout in five (5) days. This event will be uniquely recorded in the data storage system and will simultaneously start a countdown that culminates in the permanent lockout. A licensed ignition interlock technician shall remedy a permanent lockout in person. However, the Director may approve standards and procedures for an override lockout. For the purposes of this section, override lockout means a method of overriding a lockout condition by providing a breath sample indicating a negative result.
    (c)   Anytime a device is submitted pursuant to a violation reset the licensed ignition interlock technician shall perform a violation reset service consisting of, but not limited to:
    (1)   Performing maintenance and calibration in accordance with this title, and
    (2)   Retrieving all data contained in the data storage system. Proper record maintenance shall be ensured as required in this title.
[Source: Added at 27 Ok Reg 2667, eff 8-26-10; Amended at 32 Ok Reg 15369, eff 9-11-15; Amended at 36 Ok Reg 1520, eff 9-14-19; Amended at 37 Ok Reg 1001, eff 9-11-20]