SECTION 535:15-17-7. Minimum equipment  


Latest version.
  • (a)   A nuclear pharmacy shall be exempt from the physical requirements in Section 535:15-3-4, Subsections (3) through (8) and (10) through (11).
    (b)   The professional area of the pharmacy shall have at least the following equipment:
    (1)   Radionuclide Dose Calibrator;
    (2)   Refrigerator;
    (3)   Single or multiple channel scintillation counter with solid state detector (e.g. NaI(Tl) or Ge(Li));
    (4)   Radiochemical fume hood and filter system with suitable air sampling equipment when dispensing or preparing volatile radiopharmaceuticals;
    (5)   Area survey meter;
    (6)   At least two GM survey meters (including one high-range meter);
    (7)   Microscope and hemacytometer, when dispensing or preparing particle size dependent radiopharmaceuticals;
    (8)   Laminar airflow hood and appropriate supplies to ensure sterile practices for sterile compounded preparation solutions;
    (9)   Syringe and vial radiation shields;
    (10)   Appropriate shielded drawing station;
    (11)   Decontamination supplies;
    (12)   Appropriate supplies to perform quality assurance testing;
    (13)   Appropriate transport shields for syringes and vials; and
    (14)   Transport containers which meet the U.S. Department of Transportation regulations, and other labels and supplies for shipping radioactive materials.
[Source: Added at 14 Ok Reg 3027, eff 7-11-97; Amended at 24 Ok Reg 2262, eff 7-1-07; Amended at 32 Ok Reg 1229, eff 8-27-15]