SECTION 535:15-17-7. Minimum equipment
Latest version.
- (a) A nuclear pharmacy shall be exempt from the physical requirements in Section 535:15-3-4, Subsections (3) through (8) and (10) through (11).(b) The professional area of the pharmacy shall have at least the following equipment:(1) Radionuclide Dose Calibrator;(2) Refrigerator;(3) Single or multiple channel scintillation counter with solid state detector (e.g. NaI(Tl) or Ge(Li));(4) Radiochemical fume hood and filter system with suitable air sampling equipment when dispensing or preparing volatile radiopharmaceuticals;(5) Area survey meter;(6) At least two GM survey meters (including one high-range meter);(7) Microscope and hemacytometer, when dispensing or preparing particle size dependent radiopharmaceuticals;(8) Laminar airflow hood and appropriate supplies to ensure sterile practices for sterile compounded preparation solutions;(9) Syringe and vial radiation shields;(10) Appropriate shielded drawing station;(11) Decontamination supplies;(12) Appropriate supplies to perform quality assurance testing;(13) Appropriate transport shields for syringes and vials; and(14) Transport containers which meet the U.S. Department of Transportation regulations, and other labels and supplies for shipping radioactive materials.