Oklahoma Administrative Code (Last Updated: March 11, 2021) |
TITLE 748. Oklahoma Uniform Building Code Commission |
Chapter 20. Adopted Codes |
Subchapter 15. IPC® 2015 |
SECTION 748:20-15-14. IPC® 2015 Chapter 9 Vents
Latest version.
- Chapter 9 of the IPC® 2015 is adopted with the following modification: Section 903.1 Roof extension. This section has been modified to specify the number of inches where the open vent pipes that extend through the roof shall be terminated. This section has been modified to read: 903.1 Roof extension. Open vent pipes that extend through a roof shall be terminated not less than 10 inches (254 mm) above the roof. Where a roof is to be used for assembly or as a promenade, observation deck, sunbathing deck or similar purposes open vent pipes shall terminate not less than 7 feet (2134 mm) above the finished occupiable surface within 10 feet (3048 mm) horizontal distance.